Mercury Maverick 1050VA UPS

KSh 13,000.00

Mercury Maverick 1050 UPS Offline 1050VA/630W 2X Universal Socket 9AH Battery UK Power Cord

Features

Automatic restart of loads after UPS shutdown – Automatically starts up the connected equipment upon the return of utility power. Automatic self-test – Periodic battery self-test ensures early detection of a battery that needs to be replaced. Automatic Voltage Regulation (AVR) – Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment. Resettable circuit breaker – Easy recovery from overloads; no need to replace a fuse.

  • Delivery Countywide & East Africa Community
  • Warranty Guaranteed: 6 Months for Ex-UK & 1yr for Brand NEW
  • 30 Days returns & refunds
Mercury Maverick 1050VA UPS
KSh 13,000.00

[wpforms id=”1190″ title=”true” description=”Request a call back”]

Mercury is a long-known, widely used UPS brand and the new Maverick model features its latest improvements, designed to serve users’ best power backup demands.

Get an 1050VA top performance UPS in the Mercury Maverick 1050VA UPS. The advanced design Mercury Maverick UPS model is here and those who want top performance have a product worth their money and trust. Make your order today of the Mercury Maverick 850VA UPS and have it delivered to at your doorstep within 24 hours if you are outside Nairobi. If you are within the Nairobi Metropolitan area, it can be delivered to you within 2 hours of your order. Call office line on 0111 040 400 or shop online by adding it to cart and checkout.

Model:
– Capacity: 1050VA/630W

Input :
– Voltage 220-240VAC
– Voltage Range 140-300 VAC
– Frequency: 50 / 60Hz
– Current :4.8A Max

Output:
– Voltage Regulation (Bat.Mode): +/-10%
– Frequency :50 / 60Hz
– Waveform: Simulated Sine wave

Battery:
– Battery Type: 12V / 9AH x 1
– Charging ability: 6 hours recover to 90% capacity

Transfer Time:
– Typical:2-6ms

Protection : Short circuit, Overload, Battery discharge and overcharge, Surge Protection

Indications:
– Line Mode: Green lighting
– Battery Mode :Yellow flashing
– Fault: Red Lighting

Audible Alarm:
– Battery Mode: Sounding every 10 sec
– Battery low :Sounding every 1 sec
– Overload : Sounding every 0.5 sec
– Fault: Continuous sounding

Environment:
– Humidity 0-90% relative Humidity 0-40°C (Non-condensing)
– Noise Level : Less than 40dB
– Dimension: 283mm x 101mm x 140mm